Inner PVC*
Barrier
Type II, Grade 1 polyvinyl chloride conforming to ASTM/D 1784-69,
standard range 3/16" to 1/4" thick; per Duall specification
211-06
Exterior
FRP Overlay
Conforms to mechanical requirements of ASTM C 582-95 and NBS PS
15-69; standard range 1/8" to 1/2" thick; equal to GSL-1001-CNL
with a corrosion and UV-resistant exterior top coat.
Temperature
Tolerance
Stable to temperatures well over 200°F depending on the inner
liner specified.
Impact Resistance
Impact resistance varies with the inner barrier material, but is
consistently above the impact strength of FRP alone.
Ultra-Violet
Resistance
All topcoats are pigmented and contain UV inhibitors.
Corrosion
Resistance
Duall can design a DUALLast® construction that will be specifically
selected for your particular application from a wide variety of
inner laminate materials. DUALLast® construction is ideal for highly
corrosive environments such as hypochlorous acid and chlorine dioxide.
Certified
Test Data
DUALLast® construction is certified to have the following minimum
properties:
Tensile
Strength
|
10,000
PSI |
Flexural
Strength
|
10,500
PSI |
Shear
Strength
|
7,500
PSI |
| Comprehensive
Strength |
17,500
PSI |
Leakproof
Construction
Thermoplastic inner liner allows for spark tested, leakproof integrity
not always assured by FRP fabrication.
Economy
DUALLast® is a cost effective, corrosion resistant alternative to
exotic, expensive metals such as stainless steel, titanium, Hastelloy
C and others.
|