SINGLE STAGE
BETA NOx 2000
This is a high-efficiency single stage wet absorption system. This
system is used to destroy the brown/red color associated with nitrogen
dioxide. System designs can be warranted up to 99% NO2 removal based
on customer needs. If the ratio of NO2/NO is three or greater, the
system can significantly remove the nitric oxide component of NOx
as well (up to 70% removal of NO component). The system design incorporates
pH and ORP control for automatic caustic and reducer additions.
It is sometimes possible to scrub the nitrogen dioxide component
with pH control only, depending on specific conditions and requirements.
This system
is a compact, easy to use, and cost effective means to control NOx
fumes from your process equipment.
TWO STAGE
BETA NOx 2000
There are two types of dual stage scrubbing systems for NOx treatment.
The first is an oxidation/reduction system used to control both
Nitric Oxide and Nitrogen Dioxide. The equipment arrangement is
specific for the inlet condition where nitric oxide is the predominant
NOx species present. The first stage is used to oxidize excess Nitric
Oxide, with the second stage being a reduction of nitrogen dioxide.
The end product is harmless. The system uses a caustic pH control
for each recirculation tank. ORP control of the oxidation chemical
occurs in Stage 1 recycle tank and ORP control of reducer chemistry
in Stage 2 recycle tank. Warranted total NOx destruction of up to
99% is achievable with this style system.
The second
version of this two column arrangement is a caustic absorption/reduction
system used to control very high levels of Nitrogen Dioxide. This
style system is designed to minimize chemical usage of reducer by
incorporating pH control only in Stage 1 with pH/ORP controls in
Stage 2.
THREE STAGE
BETA NOx 2000
This reduction/oxidation/reduction style system is required where
Nitrogen Dioxide is the predominant NOx species present, but total
NOx control including Nitric Oxide is necessary. This system allows
for removal of the Nitrogen Dioxide component prior to oxidation
to use the oxidant more cost effectively. Stages #1, and #3 are
identical, both being Nitrogen Dioxide reducing columns. Stage #2
is the oxidizing step. Total NOx destruction of up to 99% is achievable
with this
multi-stage arrangement, while minimizing chemical costs and offering
a high degree of operational flexibility.
|
Standard
Features
- C-channel
steel skid mounted recirculation tanks with PVC corrosion resistant
coating.
- UV-resistant
thermoplastics for outdoor applications.
- Hot gas
and extrusion welded construction.
- Homogenous
thermoplastic construction
for complete corrosion resistance, and
simple repair/maintenance.
- Hydrostatic
factory testing.
- Easy pop-out
access doors.
- PVC schedule
80 piping.
- Full union
PVC ball valves.
- Sealless
vertical pumps (factory mounted).
- Packing
removal doors.
- Differential
pressure gauges.
- Heavy-duty
flanges.
- Heavy-duty
scrubber bottom.
- 316 stainless
steel hardware.
Options
- Automatic
liquid hold up valves for on/off service.
- Tank agitation.
- Automatic
control valving with proximity
position indicators.
- Variable
frequency drives.
- Balanced
ventilation systems.
- Factory
assembled and operated systems.
- Local motor
disconnects.
- Chemical
tanker off-loading stations
and storage tanks.
- Structural
framing and catwalk assemblies.
- P. E. stamped
equipment designs.
- On-line
mass balancing.
- Blowdown
waste treatment tank systems.
- Tail gas
odor control safety systems.
- PC operator
interface and PLC control system.
- High efficiency
acid aerosol fiberbed control columns.
Scrubber
System Complete Design Capability
- Wet and
dry particulate control.
- Hot gas
quenching.
- Condensers.
- Heat Exchangers.
- Multi-stage
mist collectors.
- Hoods and
duct.
|